E-25-2,4-400OI
| General information | ||
|---|---|---|
| Boiler type: | Steam boilers | |
| Equipment type: | E type (husk) | |
| Name: | E-25-2,4-400OI | |
| Fuel type: | husk | |
| Description for E-25-2,4-400OI |
|---|
| Steam boilers of this type are designed for production of saturated or overheated steam which can be used within the frames of a wide range of industries, construction facilities, municipal engineering, power production, agricultural facilities and other sectors of national economy. |
| Technical data | ||
|---|---|---|
| Capacity: | 25 | t/h |
| Output pressure: | 2.3 | MPa (kgf/cm2) |
| Output steam temperature: | 220 | C |
| Feed water temperature: | 100 | °C |
| Efficiency: | 80,4 | % |
| Fuel consumption?: | 8940 | kg/h |
| Dimensions: | 5350x3214x3992/ 5910x3220x2940/ 5910x3220x3310 | mm |
| Weight?: | 37980 | kg |
| Components | ||
|---|---|---|
| Economizer / Air-heater: | ЭБ1-646И/ ВП-О-228 | |
| FD Fan: | FDFB-10-1000 | |
| ID Fan: | IDFB-11.2-1000 | |
| Burner: | н/д | |
| Combustion chamber: | вихревая топка | |
| Pump: | н/д | |
| Control type: | н/д | |
| Other equipment: | н/д | |