MF-50/1000-II

General information
Equipment type: Forced draft fan
Name: MF-50/1000-II
English name: VM-50/1000-IIB
Notes: Radial blades
Description for MF-50/1000-II
Mill exhaust fans are designed for nonaggressive non-explosive coal dust pneumatic transport into boiler pulverized-coal system. The design of these fans allows installing them after separators, sizers and collectors under the dustiness up to 80 g/m3. It is also allowed to install such Fans in processing systems for handling nonaggressive gases (The dustiness should be not more than 80 g/m3, abrasion and sticking tendency should be similar to air-pulverized-coal mixture). Mill exhaust fans are single inlet centrifugal fans.
Aerodynamic characteristics
Capacity: 52 ths. m3/h
Total pressure: 5396 Pa
Temperature: 400 °C
Efficiency: 70 %
Dimensions*
Length (L): 2143 mm
Width (W): 2490 mm
Height (H): 2435 mm
Weight: 2770 kg
Electric motor
Actuator power?: 132 kW
Rotation frequency: 1500 rpm
Moment of inertia: н/д kg*m2
Overall drawing MF-50/1000-II *
MF-50/1000-II
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.
Railway delivery options
Platforms: 1
Wagons: 0
Transporters: 0
Additional components
Actuator: 630 Nm

help_oprosnik