General information
Equipment type: Forced draft fan
Name: MF-40/750-I
English name: VM-40/750-IB
Notes: Radial blades
Description for MF-40/750-I
Mill exhaust fans are designed for nonaggressive non-explosive coal dust pneumatic transport into boiler pulverized-coal system. The design of these fans allows installing them after separators, sizers and collectors under the dustiness up to 80 g/m3. It is also allowed to install such Fans in processing systems for handling nonaggressive gases (The dustiness should be not more than 80 g/m3, abrasion and sticking tendency should be similar to air-pulverized-coal mixture). Mill exhaust fans are single inlet centrifugal fans.
Aerodynamic characteristics
Capacity: 40 ths. m3/h
Total pressure: 7338 Pa
Temperature: 70 °C
Efficiency: 71 %
Dimensions*
Length (L): 2000 mm
Width (W): 1970 mm
Height (H): 1840 mm
Weight: 2050 kg
Electric motor
Actuator power?: 132 kW
Rotation frequency: 1500 rpm
Moment of inertia: 80 kg*m2
Overall drawing MF-40/750-I *
MF-40/750-I
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.
Railway delivery options
Platforms: 1
Wagons: 0
Transporters: 0
Additional components
Actuator: 630 Nm