IDFB-22-1000-F-C-LD

General information
Equipment type: Induced draft fan
Name: IDFB-22-1000-F-C-LD
English name: DN-22PKSH-1000
Notes: Backward curved blades
IDFB-22-1000-F-C-LD

IDFB-22-1000-F-C-LD

Description for IDFB-22-1000-F-C-LD
Single inlet centrifugal ID Fans are intended to be used for flue gas removal from combustion chambers of solid fuel or gas-and-oil-fired boilers equipped with dry ash catchers. It is allowed to install such ID Fans in processing systems for handling compatible gases (The dustiness should be not more than 2 g/m3, abrasion and sticking tendency should be similar to ashed flue gases). Such ID Fans can be applied for single or serial-parallel operation. Double inlet centrifugal ID Fans can have right-hand or left-hand rotational direction. The right-hand rotation is in a clockwise order and it should be defined at electric motor side. The main units of Single inlet centrifugal ID Fan are: running wheel, running gear, scroll casing, inlet bell and axial guide vanes. The blades of impeller are backward curved.
Aerodynamic characteristics
Capacity: 220 ths. m3/h
Total pressure: 5750 Pa
Dimensions*
Length (L): 3133 mm
Width (W): 4286 mm
Height (H): 3520 mm
Weight: 5973 kg
Electric motor
Actuator power?: 450 kW
Rotation frequency: 1000 rpm
Moment of inertia: 840 kg*m2
Overall drawing IDFB-22-1000-F-C-LD *
IDFB-22-1000-F-C-LD
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.
Railway delivery options
Platforms: 1
Wagons: 0
Transporters: 0
Additional components
Actuator: 630 Nm