High-pressure single and double inlet ID Fans with forward-curved blades are designed for flue gas removal from combustion chambers of steam boilers with the capacity of up to 640 t/h with increased resistance of flue gas path. It is also allowed to install such ID Fans in processing systems for handling compatible gases (The dustiness should be not more than 2 g/m3, abrasion and sticking tendency should be similar to ashed flue gases). Also these fans are recommended to handle gases containing trace elements with sticking tendency. High-pressure single and double inlet ID Fans can have right-hand or left-hand rotational direction. The right-hand rotation is in a clockwise order and it should be defined at electric motor side.
Aerodynamic characteristics
Capacity:
90
ths. m3/h
Total pressure:
4833
Pa
Dimensions*
Length (L):
2630
mm
Width (W):
2725
mm
Height (H):
2385
mm
Weight:
2 450
kg
Electric motor
Actuator power?:
200
kW
Rotation frequency:
1000
rpm
Moment of inertia:
155
kg*m2
Overall drawing IDF-15.5 *
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.