Return cinder fan

General information
Equipment type: Forced draft fan
Name: Return cinder fan
English name: VVU-4,3-3000
Notes: n/a
Return cinder fan

Return cinder fan

Description for Return cinder fan
Return cinder fans are designed for air delivery into return cinder equipment applied in combustion chambers of steam and hot-water solid fuel fired boilers with fuel-bed firing. Return cinder fans are recommended to use in boilers where exhaust flow high speed is required.
Aerodynamic characteristics
Capacity: 1 ths. m3/h
Total pressure: 3800 Pa
Temperature: 20 °C
Efficiency: 52 %
Dimensions*
Length (L): 466 mm
Width (W): 654 mm
Height (H): 685 mm
Weight: 107,2 kg
Electric motor
Actuator power?: 4 kW
Rotation frequency: 3000 rpm
Moment of inertia: н/д kg*m2
Overall drawing Return cinder fan *
Return cinder fan
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.
Railway delivery options
Platforms: 1
Wagons: 0
Transporters: 0
Additional components
Actuator: н/д Nm