BC-259 type battery cyclones are used for catching of ash handled by flue gases of steam or hot water boilers. Battery consists of 3 cyclone element sections working in parallel. In case of boiler low power regime two sections of such battery cyclone can be deactivated. Number 259 in cyclone name denotes the diameter of cyclone element.
Characteristics
Steam recirculation:
0,93
%
Number of elements:
6
pcs
Dust content:
37
g/m³
Resistance:
1200
Pa
Temperature:
400
°C
Purification coefficient:
90
%
Capacity 1:
4000
t/h
Dimensions*
Weight:
1820
kg
Height (H):
3500
mm
Width (W):
1430
mm
Length (L):
1580
mm
Overall drawing BC-259-(3х2) *
* Dimensions may vary depending on the electric motor model, customer requirements and design constraints.